+8618117273997weixin
InggrisInggris
中文简体 中文简体 en English ru Русский es Español pt Português tr Türkçe ar العربية de Deutsch pl Polski it Italiano fr Français ko 한국어 th ไทย vi Tiếng Việt ja 日本語

Sistem Uji ESD CDM

Pengguna manual

berlaku LISUN models: ESD-CDM

The ESD-CDM is used for CDM electrostatic testing and is fully compliant with ANSI/ESDA/JEDEC JS-002-2014, “For Electrostatic Discharge Sensitivity Testing—Charged Device Model (CDM)—Device Level.”The system primarily consists of three components: a DC high-voltage source, a test host, and an electrostatic test probe (including an attenuator). It is capable of performing electrostatic induction charging, electrostatic discharge, and discharge signal acquisition tests on charged device models (CDMs).

Ikhtisar Peralatan

Please open all packages and check the products against the packing list. If you notice any discrepancies, please contact us immediately.

Penampilan Peralatan:

CDM ESD Test System-Figure1

= 1 * GB3① HBM/MM discharge tower.
= 2 * GB3② ESD main unit.
= 3 * GB3③ CDM discharge tower.

Note: The HBM/MM module and the CDM module can share the same main unit. This model includes only the CDM module.

Instrument Front Panel:
= 1 * GB3① Touchscreen LCD, used for setting and controlling discharge parameters.
= 2 * GB3② High-voltage sockets; the discharge tower’s high-voltage cables and control wires are connected to the main unit via these sockets. Ensure the high-voltage connectors are properly connected before turning on the instrument’s power. When inserting the high-voltage plug into the high-voltage socket, align it with the socket’s positioning pin, then gently push it all the way in and tighten the retaining cap. Note: Forcibly inserting the plug without aligning it with the positioning pin may damage the fine copper pins inside the high-voltage plug.

CDM ESD Test System-Figure2

Panel belakang:
= 1 * GB3① Instrument power switch. = 2 * GB3② Power socket, with built-in fuse. = 3 * GB3③ RS232/RS485 communication port, for connecting to the CDM discharge tower.= 4 * GB3④ USB port, for connecting a mouse to control the touchscreen or a USB flash drive to upgrade the operating system. = 5 * GB3⑤ Grounding terminal; this terminal must remain properly grounded while the device is in use.

CDM ESD Test System-Figure3

Discharge Tower:

= 1 * GB3① = 2 * GB3② = 3 * GB3③ Ground connection: When the equipment is in use, these three grounding ports must be connected to ground.
= 4 * GB3④ Discharge tower control wire connection.
= 5 * GB3⑤ High-voltage electrostatic discharge cable; the other end connects to the main unit of the Electrostatic Discharge Simulator.
= 6 * GB3⑥ Red and black wires connect to the test bench.

After the main unit and the discharge tower are connected, the setup will look as shown in the figure below:

CDM ESD Test System-Figure4CDM ESD Test System-Figure5

Adjust the discharge tower height according to the sample:
= 1 * GB3① Limit block—this is the lowest adjustable position of the discharge tower;
for safety reasons, do not adjust it any lower. = 2 * GB3② Rotate to adjust the height of the discharge tower.
= 3 * GB3③ Rotate to adjust the forward and backward position of the discharge tower.

CDM ESD Test System-Figure6

Program interface. You can set the electrostatic discharge voltage, polarity, interval time, number of discharges, and other parameters.

CDM ESD Test System-Figure7

Operasi Peralatan

Complete all system wiring connections in accordance with the previous chapter and the relevant standards.

Install the test object and adjust the test stand, as well as the height and position of the discharge tower, according to the actual test object. You can first run a simulation test; the discharge tower will rise and lower automatically, and when it reaches its lowest point, it should make contact with the test point.

Set the test parameters in the program interface; once they are set, you can begin the test.

When the test is complete, replace the sample or shut down the machine.

Discharge Waveform Diagram

CDM ESD Test System-Figure8

CDM ESD Test System-Figure9

Daftar kemasan

1 ESD Host 1
2 CDM Discharge Tower 1
3 Kabel Listrik 1
4 Kawat koaksial 1
5 High-Voltage Connecting Cables 2
6 Kabel tanah 2
7 CD (berisi panduan pengguna digital, kartu garansi, sertifikat, dll.) 1

Solusi Pengujian Kinerja Fotometrik, Kolorimetrik, dan Keamanan untuk LED

Sistem Goniofotometer: LSG-6000, LSG-1890B, atau LSG-1800ACCD

Sistem Uji Spektroradiometer & Bola Integrasi: LPCE-2 or LPCE-3

LED Life Memelihara Sistem Pengujian Sesuai dengan LM-84: LEDLM-84PL

Sistem Uji Keamanan Radiasi Fotobiologis: EN 62471-C atau EN 62471-P

Sistem Pengujian Penyalaan Lampu, Waktu Pengaktifan, dan Kedipan: LSRF-3 ke LSP-500VARC-Pst

Penguji Penggerak Daya LED: LS2090, M9822, dan LSP-500VARC

Penguji Tingkat IK | Penguji Dampak Palu Pegas: IK07-10, IK01-06

Sistem Pembangkit Getaran Elektrodinamik: LVD-100KG-6D

Alat Uji Keamanan Listrik: LS9955, ZRS-3H, ZY-3, TTC-1

Solusi Uji Ruang Lingkungan untuk Luminer LED

Uji Ketahanan Air untuk IPX5 dan IPX6: JL-56

Mesin Uji Tahan Debu untuk IP5X dan IP6X: SC-015

Ruang Suhu dan Kelembaban Tinggi dan Rendah: GDJS-015B

Mesin Uji Semprot Garam: YWX/Q-010

Ruang Uji Penuaan Lampu UV: UV-263LS

Ruang Uji Penuaan Lampu Xenon: XD-80LS

Kamar Uji Ozon: OTC-150A

Ruang Uji Sulfur Dioksida: SQ-010

Solusi Pengujian EMC dan EMI untuk Luminer CFL dan LED

Sistem Uji EMI: EMI-9KB or EMI-9KA

Simulator Pelepasan Muatan Elektrostatik: ESD61000-2

Pengukuran Kekebalan EFT: EFT61000-4

Pembangkit Lonjakan: SG61000-5

Generator Penurunan dan Gangguan Tegangan: CSS61000-11

Generator Gelombang Cincin: RWG61000-12

CDM ESD Test System-Figure10

www. Lisungroup.com

Paten Diajukan

Seluruh Hak Cipta Dilindungi oleh Lisun Kelompok